IMPORTANT NOTES:
1) This manual is valid for the following Model and associated serial numbers:
MODEL SERIAL NO. REV. NO.
2) A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your par-
ticular model and serial number.
3) The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
KEPCO®
THE POWER SUPPLIER™
MODEL
OPERATOR’S MANUAL
KEPCO INC.
ORDER NO. REV. NO.
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
email: hq@kepcopower.com World Wide Web: http://www.kepcopower.com
An ISO 9001 Company.
©2014, KEPCO, INC
P/N 243-0851-g
HSP SERIES
1000 AND 1500 WATT SWITCHING POWER SUPPLY
VOLTAGE/CURRENT STABILIZED DC SOURCE
HSP SERIES
POWER SUPPLY
Vista de página 0
1 2 3 4 5 6 ... 37 38

Resumo do Conteúdo

Página 1 - OPERATOR’S MANUAL

IMPORTANT NOTES:1) This manual is valid for the following Model and associated serial numbers:MODEL SERIAL NO. REV. NO.2) A Change Page may be include

Página 2

1-4 HSPSERIES OPR 050614FIGURE 1-4. OUTLINE DRAWING

Página 3 - TABLE OF CONTENTS

HSPSERIES OPR 050614 1-51.4 MISCELLANEOUS FEATURES1.4.1 CONTROL/PROGRAMMINGa) VOLTAGE CHANNEL: Output voltage is controlled continuously throughout th

Página 4 - LIST OF TABLES

1-6 HSPSERIES OPR 0506141.4.7 AUXILIARY SUPPLY: Logic-level secondary output provides up to 0.5 watts of power at 5Vd-c. This output is isolated from

Página 5

HSPSERIES OPR 050614 1-7/(1-8 Blank)TABLE 1-3. ACCESSORIESACCESSORY PART NUMBER USERACKADAPTERSRA 58Provision for three HSP (or HSM) Power Supplies i

Página 7 - SECTION 1 - INTRODUCTION

HSPSERIES OPR 050614 2-1SECTION 2 - INSTALLATION2.1 UNPACKING AND INSPECTIONThis instrument has been thoroughly inspected and tested prior to packing

Página 8 - 1-2 HSPSERIES OPR 050614

2-2 HSPSERIES OPR 050614FIGURE 2-3. HSP SERIES REAR PANEL CONNECTIONSTABLE 2-1. I/O CONNECTOR PIN ASSIGNMENTSPIN NO. NAME DESCRIPTION OF FUNCTION

Página 9 - TEMPERATURE, POWER DERATING

HSPSERIES OPR 050614 2-32.3 SOURCE POWER REQUIREMENTSThis power supply will operate with the installed circuit breaker from single phase a-c mainspowe

Página 10 - 1-4 HSPSERIES OPR 050614

2-4 HSPSERIES OPR 0506147. Using the DVM, measure the voltage across the front panel test points “IMAX” and “COM”;this voltage is factory adjusted to

Página 11 - HSPSERIES OPR 050614 1-5

HSPSERIES OPR 050614 2-52.7.2 SOURCE POWER CONNECTIONSThe rear panel of the HSP power supply is equipped with an IEC 320 style recessed power inletcon

Página 13 - TABLE 1-3. ACCESSORIES

2-6 HSPSERIES OPR 050614Care must be taken in measuring the ripple and noise at the power supply: measuring deviceswhich are a-c line operated can oft

Página 14

HSPSERIES OPR 050614 2-72.7.5.1 LOAD CONNECTION - METHOD I (LOCAL ERROR SENSING)The most basic power supply/load interface is a 2-wire connection betw

Página 15 - SECTION 2 - INSTALLATION

2-8 HSPSERIES OPR 0506142.7.5.2 LOAD CONNECTION - METHOD II (REMOTE ERROR SENSING)If the load is located at a distance from the power supply terminals

Página 16 - 2-2 HSPSERIES OPR 050614

HSPSERIES OPR 050614 2-92.7.5.3 LOAD CONNECTION - METHOD III (SERIES CONNECTION)Units may be connected in series to obtain higher output voltages. Eac

Página 17 - HSPSERIES OPR 050614 2-3

2-10 HSPSERIES OPR 0506142.7.5.4 LOAD CONNECTION - METHOD IV (PARALLEL OPERATION)Identical HSP power supply models may be connected in parallel in ord

Página 18

HSPSERIES OPR 050614 2-11When operating power supplies in hot-swap applications, the use of an output blocking diode ismandatory to prevent excessive

Página 19 - HSPSERIES OPR 050614 2-5

2-12 HSPSERIES OPR 0506142.7.7 SIGNAL CONNECTIONSThe I/O Signal Connector, located on the rear panel of the HSP power supply (see Figure 2-3),provides

Página 20

HSPSERIES OPR 050614 3-1 SECTION 3 - OPERATING INSTRUCTIONS3.1 OPERATING CONFIGURATIONThe following subsections review the various features and indica

Página 21 - HSPSERIES OPR 050614 2-7

3-2 HSPSERIES OPR 050614c External Voltage Programming: When enabled via S2-3, this mode provides for outputvoltage adjustment via an external voltage

Página 22

HSPSERIES OPR 050614 3-3ment down to near zero. The programming method is selected via S3 switch positions 2 and 3as follows: NOTE: One programming mo

Página 23 - HSPSERIES OPR 050614 2-9

HSP OPR 050614 i/(ii Blank)TABLE OF CONTENTSSECTION PAGESECTION 1 - INTRODUCTION1.1 Scope of Manual ...

Página 24

3-4 HSPSERIES OPR 050614trols (see Figure 2-1); the jacks are labeled VO and IMAX, with a third test point labeled COMproviding access to the circuit

Página 25 - HSPSERIES OPR 050614 2-11

HSPSERIES OPR 050614 3-5The signal generated by the OVP detector is gated with a signal from the fault detector circuit toproduce a selective overvolt

Página 26

3-6 HSPSERIES OPR 0506143.10 CURRENT WALK-IN CIRCUITHSP power supplies incorporate a specialized output regulator start-up circuit for applicationsinv

Página 27 - HSPSERIES OPR 050614 3-1

HSPSERIES OPR 050614 3-73.12 REMOTE INHIBIT/REMOTE RESET CONTROLSHSP power supplies incorporate two TTL-level inputs, RC1 and RC2, accessed via the I/

Página 28

3-8 HSPSERIES OPR 050614and isolated from the ISHARE signal, so that it cannot affect the load share function if shorted.The voltage level of this sig

Página 29 - HSPSERIES OPR 050614 3-3

HSPSERIES OPR 050614 3-93.14.1 POWER INDICATOR/SOURCE POWER STATUS FLAGSMonitors available source voltage to determine if sufficient energy is availab

Página 30

3-10 HSPSERIES OPR 0506143.14.2 DCFAIL INDICATOR AND OUTPUT STATUS FLAGSThe OUTPUT status flags and DCFAIL indicator LED are both controlled by the ou

Página 31 - HSPSERIES OPR 050614 3-5

HSPSERIES OPR 050614 3-11tion of the fault detector remains unaffected by the inclusion of the meter option. The followingparagraphs describe the mete

Página 32

3-12 HSPSERIES OPR 0506143.16 BATTERY (B OPTION) OPERATIONThe Battery Charger Option (B suffix) adds a second switch-selectable voltage network to the

Página 33 - HSPSERIES OPR 050614 3-7

HSP OPR 050614 iiiTABLE OF CONTENTSSECTION PAGELIST OF FIGURESFIGURE PAGELIST OF TABLESTABLE PAGE3.13 Module Current Monitor...

Página 35 - HSPSERIES OPR 050614 3-9

iv HSPSERIES 050614FIGURE 1-1. HSP SERIES POWER SUPPLY

Página 36

HSPSERIES OPR 050614 1-1SECTION 1 - INTRODUCTION1.1 SCOPE OF MANUALThis manual contains instructions for the installation and operation of the HSP se

Página 37 - HSPSERIES OPR 050614 3-11

1-2 HSPSERIES OPR 050614TABLE 1-2. GENERAL SPECIFICATIONSCHARACTERISTIC REQUIREMENTSOURCE INPUTSource VoltageAC: Single-Phase, 1000W 1500WNomina

Página 38 - 12V HSP 15-66B 10.6 14.6

HSPSERIES OPR 050614 1-3TABLE 1-2. GENERAL SPECIFICATIONS (Continued)FIGURE 1-2. HSP (ALL), NOMINAL MAINS VOLTAGE: TEMPERATURE DERATING,FIGURE 1-3.