IMPORTANT NOTES:1) This manual is valid for the following Model and associated serial numbers:MODEL SERIAL NO. REV. NO.2) A Change Page may be include
1-4 HSPSERIES OPR 050614FIGURE 1-4. OUTLINE DRAWING
HSPSERIES OPR 050614 1-51.4 MISCELLANEOUS FEATURES1.4.1 CONTROL/PROGRAMMINGa) VOLTAGE CHANNEL: Output voltage is controlled continuously throughout th
1-6 HSPSERIES OPR 0506141.4.7 AUXILIARY SUPPLY: Logic-level secondary output provides up to 0.5 watts of power at 5Vd-c. This output is isolated from
HSPSERIES OPR 050614 1-7/(1-8 Blank)TABLE 1-3. ACCESSORIESACCESSORY PART NUMBER USERACKADAPTERSRA 58Provision for three HSP (or HSM) Power Supplies i
HSPSERIES OPR 050614 2-1SECTION 2 - INSTALLATION2.1 UNPACKING AND INSPECTIONThis instrument has been thoroughly inspected and tested prior to packing
2-2 HSPSERIES OPR 050614FIGURE 2-3. HSP SERIES REAR PANEL CONNECTIONSTABLE 2-1. I/O CONNECTOR PIN ASSIGNMENTSPIN NO. NAME DESCRIPTION OF FUNCTION
HSPSERIES OPR 050614 2-32.3 SOURCE POWER REQUIREMENTSThis power supply will operate with the installed circuit breaker from single phase a-c mainspowe
2-4 HSPSERIES OPR 0506147. Using the DVM, measure the voltage across the front panel test points “IMAX” and “COM”;this voltage is factory adjusted to
HSPSERIES OPR 050614 2-52.7.2 SOURCE POWER CONNECTIONSThe rear panel of the HSP power supply is equipped with an IEC 320 style recessed power inletcon
2-6 HSPSERIES OPR 050614Care must be taken in measuring the ripple and noise at the power supply: measuring deviceswhich are a-c line operated can oft
HSPSERIES OPR 050614 2-72.7.5.1 LOAD CONNECTION - METHOD I (LOCAL ERROR SENSING)The most basic power supply/load interface is a 2-wire connection betw
2-8 HSPSERIES OPR 0506142.7.5.2 LOAD CONNECTION - METHOD II (REMOTE ERROR SENSING)If the load is located at a distance from the power supply terminals
HSPSERIES OPR 050614 2-92.7.5.3 LOAD CONNECTION - METHOD III (SERIES CONNECTION)Units may be connected in series to obtain higher output voltages. Eac
2-10 HSPSERIES OPR 0506142.7.5.4 LOAD CONNECTION - METHOD IV (PARALLEL OPERATION)Identical HSP power supply models may be connected in parallel in ord
HSPSERIES OPR 050614 2-11When operating power supplies in hot-swap applications, the use of an output blocking diode ismandatory to prevent excessive
2-12 HSPSERIES OPR 0506142.7.7 SIGNAL CONNECTIONSThe I/O Signal Connector, located on the rear panel of the HSP power supply (see Figure 2-3),provides
HSPSERIES OPR 050614 3-1 SECTION 3 - OPERATING INSTRUCTIONS3.1 OPERATING CONFIGURATIONThe following subsections review the various features and indica
3-2 HSPSERIES OPR 050614c External Voltage Programming: When enabled via S2-3, this mode provides for outputvoltage adjustment via an external voltage
HSPSERIES OPR 050614 3-3ment down to near zero. The programming method is selected via S3 switch positions 2 and 3as follows: NOTE: One programming mo
HSP OPR 050614 i/(ii Blank)TABLE OF CONTENTSSECTION PAGESECTION 1 - INTRODUCTION1.1 Scope of Manual ...
3-4 HSPSERIES OPR 050614trols (see Figure 2-1); the jacks are labeled VO and IMAX, with a third test point labeled COMproviding access to the circuit
HSPSERIES OPR 050614 3-5The signal generated by the OVP detector is gated with a signal from the fault detector circuit toproduce a selective overvolt
3-6 HSPSERIES OPR 0506143.10 CURRENT WALK-IN CIRCUITHSP power supplies incorporate a specialized output regulator start-up circuit for applicationsinv
HSPSERIES OPR 050614 3-73.12 REMOTE INHIBIT/REMOTE RESET CONTROLSHSP power supplies incorporate two TTL-level inputs, RC1 and RC2, accessed via the I/
3-8 HSPSERIES OPR 050614and isolated from the ISHARE signal, so that it cannot affect the load share function if shorted.The voltage level of this sig
HSPSERIES OPR 050614 3-93.14.1 POWER INDICATOR/SOURCE POWER STATUS FLAGSMonitors available source voltage to determine if sufficient energy is availab
3-10 HSPSERIES OPR 0506143.14.2 DCFAIL INDICATOR AND OUTPUT STATUS FLAGSThe OUTPUT status flags and DCFAIL indicator LED are both controlled by the ou
HSPSERIES OPR 050614 3-11tion of the fault detector remains unaffected by the inclusion of the meter option. The followingparagraphs describe the mete
3-12 HSPSERIES OPR 0506143.16 BATTERY (B OPTION) OPERATIONThe Battery Charger Option (B suffix) adds a second switch-selectable voltage network to the
HSP OPR 050614 iiiTABLE OF CONTENTSSECTION PAGELIST OF FIGURESFIGURE PAGELIST OF TABLESTABLE PAGE3.13 Module Current Monitor...
iv HSPSERIES 050614FIGURE 1-1. HSP SERIES POWER SUPPLY
HSPSERIES OPR 050614 1-1SECTION 1 - INTRODUCTION1.1 SCOPE OF MANUALThis manual contains instructions for the installation and operation of the HSP se
1-2 HSPSERIES OPR 050614TABLE 1-2. GENERAL SPECIFICATIONSCHARACTERISTIC REQUIREMENTSOURCE INPUTSource VoltageAC: Single-Phase, 1000W 1500WNomina
HSPSERIES OPR 050614 1-3TABLE 1-2. GENERAL SPECIFICATIONS (Continued)FIGURE 1-2. HSP (ALL), NOMINAL MAINS VOLTAGE: TEMPERATURE DERATING,FIGURE 1-3.